  31   11 Jul 2019 15:52 ThomasRoutineTriggerinvert first chronobox busy signal
The DAQ seems to be ready for tests with proto-0 tomorrow.  

I had to invert the first busy input in order to get chronobox to produce triggers.  I modified the setup script

setup_chronobox.sh

so this is now the default.  Not sure why necessary.

Another interesting fact; it seems the chronobox only asks for a DHCP IP when it first boots.  I think that
chronobox and ds-proto-daq were rebooted at the same time; ds-proto-daq dhcp server was probably not running
when chronobox asked for IP.  chronobox got IP fine when it was power cycled.
  34   12 Jul 2019 06:01 Marco RescignoRoutineGeneralRun 703

Run 703 is being writte on disk.

16 channels of board 00. 

Laser trigger at 10 Hz

ended with

[feoV1725.cxx:1033:read_trigger_event,ERROR] Error: did not receive a ZMQ bank. Stopping run.   ]

  35   12 Jul 2019 07:58 Marco RescignoRoutineGeneralMB1 test in proto-0 setup/day 2

Implemented a simple charge integration on the midas display, most of the channels look almost as good as this one.

Nothing on the daq side changed, a part from the DAC value moved to 5000, allowing a slightly greater dynamic range.

Attachment 1: Screenshot_from_2019-07-13_17-45-14.png
Screenshot_from_2019-07-13_17-45-14.png
  36   12 Jul 2019 11:34 Marco RescignoRoutineGeneralMB1 test in proto-0 setup/2 Run 718

Run 718 has 25 channel readout Board 0 ch 0-15 and Board 0 ch 0-7. 

Laser triggered, some noise, maybe not so bad as is look here.

RMS of baseline is 200 ADC count. Single PE peak is about 100-200 ADC count from baseline.

Looking carefully, some very nice scintillation event are found.

 

 

 

 

Attachment 1: RMS_run718.gif
RMS_run718.gif
Attachment 2: SPE.gif
SPE.gif
Attachment 3: Scintillation.gif
Scintillation.gif
  37   13 Jul 2019 14:50 Marco RescignoRoutineGeneralLong Laser run on disk

Run 747 , 250 k events

as requested by alessandro 40% post trigger, acquisition window 16 us.

 

  38   16 Jul 2019 01:58 Marco RescignoRoutineGeneralRun 766 (Laser)

Laser Run with Vbias=65 V , new recommended value from PE group

500 k events acquired

  39   16 Jul 2019 02:39 Marco RescignoRoutineGeneralrun 771, scintillation events triggering on ch11 and ch12 of board0

Trigger setup with a threshold of 1500 ADC count wrt to baseline, on just two channels.

This is also to limit the trigger to 50 Hz, since the busy still did not work.

100 K events on disk.

  41   16 Jul 2019 03:17 Marco RescignoRoutineGeneralrun 772, scintillation events triggering on all channels

Majority of 5, threshold at 1000 ADC count, 13 channels enabled (10 trigger signals)  50 Hz, 30 us window.

58 k events recorded.

  42   16 Jul 2019 03:51 Marco RescignoRoutineGeneralrun 773, scintillation events triggering on all 24 channels

Majority of 5, threshold at 1000 ADC count, 24 channels enabled (16 trigger signals)  100 Hz, 30 us window.

38 k events recorded.

  43   16 Jul 2019 03:53 Marco RescignoRoutineGeneralrun 774, scintillation events triggering on all 24 channels and 200 us window

Majority of 8, threshold at 1000 ADC count, 24 channels enabled (16 trigger signals)  10 Hz, 200 us window, trigger at 9.5 microseconds.

10 k events recorded.

By direct inspection pileup seems at the 10 % level in the 200 us window.

Attachment 1: PileupEvent.png
PileupEvent.png
  44   25 Oct 2019 07:17 Simone StrackaRoutineHardwarePhotoelectronics activities on October, 24

Crew: Edgar Sanchez Garcia, Sam Hill, Simone Stracka, Tom Thorpe, Yi Wang

Morning: Tested photocurrents for MB2 on tabletop using SMU and Keithley switching matrix.  All measured between 1-10 microAmps.

Afternoon: Tested PDU mounting procedure with TPC assembled and with the mockup.  No showstoppers. This will be the procedure for installation
With the mockup on the table we double checked the resistances.  Confirmed all values are as before cooling indicating no additional damage to the wire-bondings.

 

  45   25 Oct 2019 07:44 Simone StrackaRoutineHardwareMB2 activities on October 25
Crew: Edgar Sanchez Garcia, Sam Hill, Simone Stracka, Tom Thorpe, Yi Wang

Morning: Set up equipment for the IV curve measurements. We enable the interlock system in the SMU in order to go higher than 42 V (handle with care).

Afternoon:  Measuring IV curves.  Note there is a voltage drop in the LV cable that needs to be compensated for.  

Chan 1 is set at +3.3V drawing 1.46A; sense line reads +2.39V
Chan 2 is set at -3.3V drawing 1.46A; sense line reads -2.39V
IV curves are scanning from 0-80V in 200mV steps w/ 100uA limit: elog:45/2 , elog:45/3
The two runs are visible ( elog:45/1 for color code and mapping )
Compare to elog:45/4 , obtained when probing individual tiles under more controlled light conditions
Attachment 1: TileFEBMapping_MB2.png
TileFEBMapping_MB2.png
Attachment 2: iv_warm_1.png
iv_warm_1.png
Attachment 3: iv_warm_1_zoom.png
iv_warm_1_zoom.png
Attachment 4: IndividualTileAtLNGS.png
IndividualTileAtLNGS.png
  56   01 Nov 2019 09:06 Alex KishRoutineGeneralrun 826, zero-field with gas pocket

Gas pocket: ON

Fields: OFF

Threshold: 400 ADCc below baseline

Threshold extend:  5x16 = 80ns

Comment: Noise appeared on event 4200

  60   01 Nov 2019 10:56 Alex / MarcoRoutineGeneralrun 829, with nominal fields

Gas pocket: ON

Fields: ON

Threshold: 200 ADCc below baseline

Threshold extend:  5x16 = 80ns

Comment: Noise appeared on event 48500

  61   03 Nov 2019 07:46 Alex KishRoutineGeneralrun 833, with nominal fields

Gas pocket: ON

Fields: ON (wire gate 3780 V, 1st ring 4180 V, cathode 6180 V)

Threshold: 200 ADCc below baseline

Threshold extend:  5x16 = 80ns

TPC Pressure: 242 mbarg

SiPM HV: 65V

Comment: noise conditions good, 1e5 evts

  62   03 Nov 2019 08:15 Alex KishRoutineGeneralrun 834, drift field ON, extraction OFF

Gas pocket: ON

Fields: drift field ON (1st ring 4180 V, cathode 6180 V), extraction field OFF (wire gate 0 V)

Threshold: 200 ADCc below baseline

Threshold extend:  5x16 = 80ns

TPC Pressure: 244 mbarg

SiPM HV: 65 V

Comment: noise conditions good, 1e5 evts

  63   03 Nov 2019 08:49 Alex KishRoutineGeneralrun 835, zero drift field

Gas pocket: ON

Fields: drift field OFF (1st ring 0 V, cathode 0 V), extraction field OFF (wire gate 0 V)

Threshold: 200 ADCc below baseline

Threshold extend:  5x16 = 80ns

TPC Pressure: 244 mbarg

SiPM HV: 65 V

Comment: noise conditions good, 1e5 evts

  64   03 Nov 2019 09:17 Alex KishRoutineGeneralrun 836, zero drift field

Gas pocket: ON

Fields: drift field OFF (1st ring 0 V, cathode 0 V), extraction field OFF (wire gate 0 V)

Threshold: 200 ADCc below baseline

Threshold extend:  5x16 = 80ns

TPC Pressure: 244 mbarg

SiPM HV: 50 V (noise run)

Comment: noise conditions good. Thresholds are too high, rate below 1 event/sec, only few events saved. Postpone to next day.

  68   04 Nov 2019 08:03 Ben SmithRoutineSoftwareNew script for setting self-trigger thresholds
I have created a new script that simplifies the adjustment of self-trigger thresholds (e.g. to change between "noise" runs with a low threshold and "normal" runs with a higher threshold).

It supports either setting the threshold to a certain number of ADC beneath baseline, or just shifting all the current thresholds by a given amount. It can also be used to just print the current baseline of each channel. Baseline calculation is done "live" by reading a few events.

The code is available in dsproto_analyzer, and is documented at https://bitbucket.org/ttriumfdaq/dsproto_daq/wiki/Midas%20Software%20Operation (scroll to "Adjusting self-trigger thresholds"). We used it recently to change to a noise run, and it worked well.
  69   04 Nov 2019 09:02 Alex/Yi/BenRoutineGeneralrun 865, fields on

Gas pocket: ON

Fields: wire gate 3780 V, 1st ring: 4500 V, cathode: 7000 V

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure: 300 mbarg

SiPM HV: 65 V (noise run)

Comment: noise conditions good. Rate ~30Hz. Look for S2s!