HW-Time-Slice Firmware-Filter Software vx2740 Steering Module Reports MVM MVM Vexos MVM-Bug listing MVM TRIUMF Local DS Prototype DS Cryogenic For Shifters BCIT-31 ChronoBox Run Operation DS-DAQ
  CERN DS-Proto0 read-only backup  Not logged in ELOG logo
Message ID: 31     Entry time: 11 Jul 2019 15:52
Author: Thomas 
Type: Routine 
Category: Trigger 
Subject: invert first chronobox busy signal 
The DAQ seems to be ready for tests with proto-0 tomorrow.  

I had to invert the first busy input in order to get chronobox to produce triggers.  I modified the setup script

setup_chronobox.sh

so this is now the default.  Not sure why necessary.

Another interesting fact; it seems the chronobox only asks for a DHCP IP when it first boots.  I think that
chronobox and ds-proto-daq were rebooted at the same time; ds-proto-daq dhcp server was probably not running
when chronobox asked for IP.  chronobox got IP fine when it was power cycled.
ELOG V3.1.4-cb3afcd8