  131   14 Nov 2019 04:03 Yi/Edgar/SamRoutineGeneralNoise data taking

Run 1121 

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 50 V (lower than breakdown voltage) 

Number of events: 5k

 

Run 1122 

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 63 V

Number of events: 5k

Without blanket 

 

Run 1125

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 5k

Without blanket 

 

Run 1126

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 67 V

Number of events: 3.5k

trigger rate went down to 1 Hz, run was stopped manually

Without blanket 

 

Run 1127

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 67 V

Number of events: 2k

Without blanket 

 

Run 1128

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 67 V

Number of events: 5k

With blanket 

trigger rate went down to 1 Hz, run was stopped manually

problem with DAQ forced to restart manually 

Run 1129

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 67 V

Number of events: 5k

With blanket 

trigger rate went down to 1 Hz, run was stopped manually

problem with DAQ forced to restart manually 

jsroot_server stops from time to time 

1573739641 14:54:01.099 2019/11/14 [Logger,INFO] Client 'jsroot_server' on buffer 'SYSTEM' removed by cm_periodic_tasks because process pid 26693 does not exist

Run 1130

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 67 V

Number of events: 5k

With blanket 

 

Run 1131

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 5k

With blanket 

Run 1132

Gas pocket: OFF

Fields:  OFF

Threshold: external clock, 50Hz

Trace length: 1ms total, 600 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 5k

With blanket 

 

  130   14 Nov 2019 03:51 E. SanchezRoutineGeneralS1 data taking without field

Run 1133

Gas pocket: OFF

Fields: OFF

Threshold: 100 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 2 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1134

Gas pocket: OFF

Fields: OFF

Threshold: 200 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 2 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1135

Gas pocket: OFF

Fields: OFF

Threshold: 400 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 2 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1136

Gas pocket: OFF

Fields: OFF

Threshold: 600 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 2 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1137

Gas pocket: OFF

Fields: OFF

Threshold: 1000 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 2 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1138

Gas pocket: OFF

Fields: OFF

Threshold: 100 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 3 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1139

Gas pocket: OFF

Fields: OFF

Threshold: 200 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 3 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

 

Run 1140

Gas pocket: OFF

Fields: OFF

Threshold: 400 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 3 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1141

Gas pocket: OFF

Fields: OFF

Threshold: 600 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 3 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1142

Gas pocket: OFF

Fields: OFF

Threshold: 1000 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 3 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1143

Gas pocket: OFF

Fields: OFF

Threshold: 100 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 5 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1144

Gas pocket: OFF

Fields: OFF

Threshold: 200 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 5 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1145

Gas pocket: OFF

Fields: OFF

Threshold: 400 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 5 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1146

Gas pocket: OFF

Fields: OFF

Threshold: 600 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 5 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

Run 1147

Gas pocket: OFF

Fields: OFF

Threshold: 1000 ADCc below baseline

Trace length: 30us total, 5 us pre-trigger

Coincidence: 5 PDMs

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 50k

  129   14 Nov 2019 00:33 E. SanchezRoutineGeneralMorning data taking

It is not possible to access to the Chronobox page

Run 1109 Laser run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Laser Intensity: MIN

Threshold: external clock (laser NIM), laser set to 1kHz

Trace length: 12us, 5us pre-trigger

SIPM HV: 65V

Number of events: 100k

 

Run 1110 Laser run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Laser Intensity: MAX

Threshold: external clock (laser NIM), laser set to 1kHz

Trace length: 12us, 5us pre-trigger

SIPM HV: 65V

Run 1112

Gas pocket: ON (thinkness 7mm)

Fields: OFF 

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 10k

Run 1113

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 2.8 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Run 1114

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Run 1115

Gas pocket: ON (thinkness 7mm)

Fields: drift 500 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

 

 

 

  128   14 Nov 2019 00:09 Ben SmithProblemHardwareChronobox not serving human webpage
The chronobox isn't serving the human-interactive webpage that should be visible at https://m-darkside.web.cern.ch/chronobox/ - it responds with "File not found". Oddly, it is still responding to API calls at /read_var, /write_var etc.

So shifters can still change between laser/noise/physics runs using the "Run type" page at https://m-darkside.web.cern.ch/?cmd=custom&page=Run%20type (which uses the API), but can't as easily monitor / sanity check the chronobox behaviour.

In the first instance, I think it would be useful to power-cycle the chronobox. If that doesn't work, I'm not sure how to proceed.
  127   13 Nov 2019 09:24 Xiang XiaoRoutineGeneralEvening data taking

Run 1105

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  265 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1106

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 2.8 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  252 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1107

Gas pocket: ON (thinkness 7mm)

Fields: drift 500 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1108

Gas pocket: ON (thinkness 7mm)

Fields: OFF

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  242 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Comment: Webpage of Chronobox doens't work, skipped Laser runs.

  126   13 Nov 2019 08:15 Ben SmithRoutineSoftwareDon't worry about "Param Not Found Type" error messages
When we start the HV program (CAEN_SY4527), it spews error messages of the form:
"16:58:30.035 2019/11/13 [CAEN_SY4527,ERROR] [dd_sy4527.cxx:280:fParam_get,ERROR] Param Not Found Type : 0"

This is because the LV module in the SY5527 crate doesn't support some of the parameters that the driver wants to read 
(e.g. it support "RUpTime" rather than "RUp"). For our current usage, the errors are benign. But it does add to the list 
of deficiencies of the driver provided by core midas:
* No automatic discovery of total number of channels
* Confusing ODB structure
* No discovery of which features a module supports
* Odd detection of whether a channel is on/off
* ODB status doesn't update if module settings are changed with a different interface (e.g. SSH or Caen's Java-based GUI).

All these limitations are imposed by the core HV driver "class" in midas. Assuming we will be using Caen HV modules for the
foreseeable future, I think I should write a new slow control frontend that is less generic, but fixes all the above issues.
  125   13 Nov 2019 00:08 Yi WangRoutineGeneralMorning data taking

Run 1099

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  250 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1100

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 500 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  250 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1101

Gas pocket: ON (thinkness 7mm)

Fields: drift 500 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  250 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1102

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 2.8 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  250 mbarg

SiPM HV: 65 V

Number of events: 10k

 

Run 1103

Gas pocket: ON (thinkness 7mm)

Fields: OFF

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  250 mbarg

SiPM HV: 65 V

Number of events: 10k

  124   12 Nov 2019 10:08 Edgar SanchezRoutineGeneralLaser run

Run 1096 Laser run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Laser Intensity: MAX

Threshold: external clock (laser NIM), laser set to 1kHz

Trace length: 12us, 5us pre-trigger

SIPM HV: 65V

Number of events: 100k

 

Run 1097 Laser run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Laser Intensity: MIN

Threshold: external clock (laser NIM), laser set to 1kHz

Trace length: 12us, 5us pre-trigger

SIPM HV: 65V

Number of events: 100k

Problem: The access to the Chronobox page is not possible.  Rate 400 Hz 

  123   12 Nov 2019 09:30 Edgar SanchezRoutineGeneralAfternoon system monitoring

Run 1092

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

Run 1093

Gas pocket: ON (thinkness 7mm)

Fields: drift 500 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

Run 1094

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 2.8 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

Run 1095

Gas pocket: ON (thinkness 7mm)

Fields: OFF 

Threshold: 1000 ADCc below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

  122   12 Nov 2019 09:22 Edgar SanchezRoutineGeneralAfternoon system monitoring

Run 1090

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 100us total, 50 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

Run 1091

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 400 ADCc below baseline

Trace length: 100us total, 50 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  220 mbarg

SiPM HV: 65 V

Number of events: 10k

  121   12 Nov 2019 00:24 Yi WangRoutineGeneralMorning data taking

Run 1084

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 500 ADCc below baseline

Trace length: 100us total, 50 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 20k

 

Run 1085

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 200 ADCc below baseline

Trace length: 100us total, 50 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 20k

 

Run 1086

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 100us total, 50 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  240 mbarg

SiPM HV: 65 V

Number of events: 6k

Run crashed: 09:31:55.239 2019/11/12 [feov1725MTI00,ERROR] [feoV1725.cxx:663:link_thread,ERROR] Exiting thread 0 with error

  120   12 Nov 2019 00:23 Ben SmithProblemDigitizerV1725 error, runs keep crashing
It looks like there's a memory leak in the high voltage driver, and we were running out of memory (using a lot of swap). That *may* be related to the recent instability, but I'm not sure.

If things are more stable now, then the memory leak was probably the cause. If not, then we should try stopping the V1725 program, power-cycling the VME crate, then starting the V1725 program.


Yi: restarted the VME crate twice, now it seems like smooth.
  119   12 Nov 2019 00:16 Yi WangProblemDigitizerV1725 error, runs keep crashing

09:15:33.955 2019/11/12 [feov1725MTI00,ERROR] [feoV1725.cxx:663:link_thread,ERROR] Exiting thread 3 with error

  118   11 Nov 2019 23:57 Yi WangProblem FixedTriggerID 117 problem is fixed

The problem reported in ID 117 is somehow fixed this morning.

  117   11 Nov 2019 10:05 Sam HillProblemGeneralEvening data taking

Attemted the following run, and it started but the rate was shoing 0 and it got stuck on 5 events

Was unable to connect to Chronobox webpage even after turning VME crate off and on.

Abandoned run and will attempt to fix in the morning.

Run 1073

Gas pocket: ON (thickness unknown)

Fields:  drift 200 V/cm, extraction 2.8 kV/cm

Threshold: 1000 ADC below baseline

Trace length: 200us total, 100 us pre-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  252mbarg

SiPM HV: 65 V

Number of Events: 10K

 

  116   11 Nov 2019 09:31 Sam HillRoutineGeneralAfternoon system monitoring: IV curves and Dewar refill

17:30

Took a set of IV curves using 0.5V steps from 30-50V and 0.05 steps above 50V.

Curves all look as expected, although reducing the step size makes the breakdown voltage harder to see on the plots.

Will use 0.02V steps in future.

Data can be found on dsproto machine at: /home/dsproto/online/dsproto_sy4527/ivdata_191111

Summary plot attached to this entry.

19:15

Refilled outer dewar for 10 mins

Attachment 1: summaryPlot_191111.png
summaryPlot_191111.png
  115   11 Nov 2019 01:12 Yi / EdgarRoutineGeneralMorning data taking

Run 1065

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 1000 ADCc below baseline

Trace length: 100us total, 80 us post-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  260 mbarg

SiPM HV: 65 V

Number of events: 20k

 

Run 1066

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 500 ADCc below baseline

Trace length: 100us total, 80 us post-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  260 mbarg

SiPM HV: 65 V

Number of events: 20k

 

Run 1067

Gas pocket: ON (thinkness 7mm)

Fields: drift 200 V/cm, extraction 3.78 kV/cm

Threshold: 200 ADCc below baseline

Trace length: 100us total, 80 us post-trigger

Threshold extend:  5x16 = 80ns

TPC Pressure:  260 mbarg

SiPM HV: 65 V

Number of events: 20k

  114   11 Nov 2019 00:47 Yi / EdgarProblem FixedDigitizerProblem fixed by restarting the VME crate
  113   11 Nov 2019 00:37 Yi WangProblemMIDAScannot connect to rootana

The connection to rootana is lost.

No data taking can be started.

  112   10 Nov 2019 12:15 E. SanchezProblemMIDASProblem DAQ

Error during data taking  1573416708 21:11:48.151 2019/11/10 [feov1725MTI00,INFO] V1725 PLL loss lock Board:0 (vmeAcq=0x0)

It stop saving event but run in process. Impossible to stop the run. I tried to reset feov1725MTl00. After that error: 

1573416857 21:14:17.792 2019/11/10 [feChronoEsper,INFO] Client 'feov1725MTI00' on database 'ODB' removed by db_cleanup called by cm_periodic_tasks because pid 9724 does not exist

Run stopped after some time. Error 21:21:19.121 2019/11/10 [mhttpd,ERROR] [midas.cxx:3951:cm_transition_call,ERROR] cannot connect to client "feov1725MTI00" on host localhost, port 40944, status 503   ╳

Trying to restart feov1725MTI00. Status initializing

It is not possible to initialize 

 

 