ID |
Date |
Author |
Type |
Category |
Subject |
Text |
|
83
|
05 Nov 2019 08:14 |
Alex / Sam | Routine | General | Run 898, Edrift 200V/cm | Gas pocket: ON (thinkness
unknown, since the TPC pressure is >200
mbar) [Edgar\Yi: correction: |
|
84
|
05 Nov 2019 08:23 |
Alex / Sam | Routine | General | Run 899, Edrift 100V/cm | Gas pocket: ON (thinkness
unknown, since the TPC pressure is >200
mbar) [Edgar\Yi: correction: |
|
85
|
05 Nov 2019 08:32 |
Alex / Sam | Routine | General | Run 900, Edrift 500V/cm | Gas pocket: ON (thinkness
unknown, since the TPC pressure is >200
mbar) [Edgar\Yi: correction: OFF (during |
|
86
|
05 Nov 2019 23:58 |
Yi Wang | Routine | General | Morning data taking, purity check | Run 917
Gas pocket: ON
(thinkness 7mm) |
|
87
|
06 Nov 2019 05:58 |
Ben Smith | Configuration | Hardware | CAEN VME Crate DHCP | The CAEN VME crate now gets its IP address
from the ds-proto-daq DHCP server. To do
this, I set the IP address of the crate to |
|
88
|
06 Nov 2019 11:22 |
Yi Wang | Routine | General | Evening data taking, purity check | Not sure if the trigger threshold is correctly
set, there is an error:
Traceback (most recent call last): |
|
89
|
06 Nov 2019 12:28 |
Ben Smith | Problem Fixed | General | Evening data taking, purity check | > Not sure if the trigger threshold is correctly
set, there is an error:
|
|
90
|
07 Nov 2019 02:07 |
Sam | Routine | General | Run 963 Laser Run with SiPMs at 65V, 12us trace | Laser Intensity: MAX
Threshold: external
clock (laser NIM), laser set to 1kHz |
|
91
|
07 Nov 2019 02:07 |
Yi/Marco/Andrea | Routine | General | morning data taking, purity check | Run 956
Gas pocket: ON
(thickness 7mm) |
|
92
|
07 Nov 2019 02:16 |
Sam | Routine | General | Run 964 Laser Run with SiPMs at 65V, 30us trace | Laser Intensity: MAX
Threshold: external
clock (laser NIM), laser set to 1kHz |
|
93
|
07 Nov 2019 02:34 |
Sam | Routine | General | Run 966 Laser Run with SiPMs at 65V, 30us trace | Laser Intensity: MIN
Threshold: external
clock (laser NIM), laser set to 1kHz |
|
94
|
07 Nov 2019 23:48 |
Yi Wang | Routine | General | morning data taking | Run 973
Gas pocket: ON
(thinkness 7mm) |
|
95
|
08 Nov 2019 02:21 |
Ben Smith | Problem Fixed | Software | Increased max waveform length that we can take | I've increased various thresholds so that
we can now take 3000us (3ms) waveforms.
|
|
96
|
08 Nov 2019 02:31 |
Ben Smith | Routine | Software | New "run type" selection page | I made a new page that makes it easier to
switch between laser/noise/physics runs.
|
|
97
|
08 Nov 2019 02:48 |
Ben Smith | Configuration | MIDAS | Enabled dotfile naming in Logger | I have changed `/Logger/Channels/0/Settings/Filename`
to start with a dot, so files will be hidden
until they are complete.
|
|
98
|
08 Nov 2019 05:14 |
Ben Smith | Configuration | Hardware | Adding darkside01 to the network | The analysis server from Roma (darkside01)
is now connected to the local network. It
is not yet connected to CERN.
|
|
99
|
08 Nov 2019 08:35 |
Ben Smith | Configuration | Hardware | Failed to talk to steering module from DAQ PC | I have failed to communicate with the steering
module arduino from the DAQ PC.
|
|
100
|
08 Nov 2019 09:09 |
Ben Smith | Configuration | Hardware | Adding darkside01 to the network | The cable has been fixed. Socket 0001/007
is still not active. |
|
101
|
08 Nov 2019 10:07 |
Edgar Sanchez | Routine | General | Monitoring Data Taking | Run 995
Gas pocket: ON
(thinkness 7mm) |
|
103
|
08 Nov 2019 22:31 |
Marco | Configuration | Hardware | Adding darkside01 | Wrong MAC address fixed in CERN network
setting, now the machine is visible from
external network too: |
|