Message ID: 99     Entry time: 08 Nov 2019 08:35
Author: Ben Smith 
Type: Configuration 
Category: Hardware 
Subject: Failed to talk to steering module from DAQ PC 
I have failed to communicate with the steering module arduino from the DAQ PC.

The steering module has the most bizarre communication protocol of any device I have used:
* it has a static IP address (192.168.121.2)
* if something connects and sends a command, it doesn't send a response to that device - it sends responses to a different static IP address on a fixed port
* before a device connects, it's ethernet port is not open all the time - it turns it on for a brief period, and if something connects during that period, it remains on; if not, it turns off for a while. I'd estimate something like on for 500ms, off for 500ms.

We are currently using a macbook to connect to the steering module. The macbook is statically assigned IP address 192.168.121.1. When pinging the steering module, then first few pings fail with "no route to host". Eventually one of the pings coincides with the steering module having its ethernet on, and then the steering module keeps its ethernet on and the rest of the pings succeed.

We bought a new NIC for DAQ machine. I assigned it same static IP address (192.168.121.1), added a hole in the firewall (and even tried turning the firewall off for a bit), ensured the correct interface was used for connections to 192.168.121.0/24, but we never get a route to the steering module.

I have run out of things to try (but I may have missed something). My hypothesis is that linux isn't able to negotiate a connection quickly enough, but I may be wrong. It is my last evening at CERN, so I have returned the steering module to be connected to the macbook. Shifters will continue to have to manually change channels rather than having it automated by midas.

I hope that future versions of the steering module will have a more normal network protocol - open a server socket (static if must be, but preferably on DHCP), wait for connections, reply to commands on that same connection.