111
|
10 Nov 2019 11:19 |
Edgar Sanchez | Routine | General | S1 + S2 short time window | Run 1054
Gas pocket: ON (unknow)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 100 ADC below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
|
110
|
10 Nov 2019 11:18 |
Edgar Sanchez | Routine | General | Afternoon system monitoring | Run 1050
Gas pocket: ON (unknow)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 245 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1051
Gas pocket: ON (unknow)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 260 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1052
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 245 mbarg
SiPM HV: 65 V
Number of events: 10k
Stopped. Problem with DAQ |
109
|
10 Nov 2019 08:40 |
Edgar Sanchez | Routine | General | S1 data taking without field | Run 1041
Gas pocket: OFF
Fields: OFF
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 360 Hz
Run 1042
Gas pocket: OFF
Fields: OFF
Threshold: 200 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 340 Hz
Run 1043
Gas pocket: OFF
Fields: OFF
Threshold: 250 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 290 Hz
Run 1044
Gas pocket: OFF
Fields: OFF
Threshold: 400 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 240 Hz
Run 1045
Gas pocket: OFF
Fields: OFF
Threshold: 600 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 170 Hz
Run 1046
Gas pocket: OFF
Fields: OFF
Threshold: 800 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 140 Hz
Run 1047
Gas pocket: OFF
Fields: OFF
Threshold: 1000 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 110 Hz
Run 1048
Gas pocket: OFF
Fields: OFF
Threshold: 150 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
Run 1049
Gas pocket: OFF
Fields: OFF
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz |
108
|
10 Nov 2019 08:04 |
Edgar Sanchez | Routine | General | S1 data taking with field | Run 1032
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 800 Hz
Run 1033
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 200 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 350 Hz
Run 1034
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 250 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 260 Hz
Run 1035
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 400 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 200 Hz
Run 1036
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 600 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 130 Hz
"ERROR INFO: 17:19:23.176 2019/11/10 [feov1725MTI00,ERROR] [feoV1725.cxx:1048:read_trigger_event,ERROR] Error: did not receive a ZMQ bank after 100.000000 ms. Stopping run."
Run 1037
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 800 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 110 Hz
Run 1038
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 80 Hz
Run 1039
Gas pocket: OFF
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 150 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 340 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
|
107
|
10 Nov 2019 00:06 |
Yi Wang | Routine | General | morning data taking | Run 1022
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADCc below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 159 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1024
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 186 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1025
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 207 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1026
Gas pocket: ON (thinkness 7mm)
Fields: OFF
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 225 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1028 Laser run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MAX
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Number of events: 100k
Run 1029 Laser run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Number of events: 100k |
106
|
09 Nov 2019 09:39 |
Sam Hill | Routine | General | Evening data taking | Run 1016
Gas pocket: ON (thinkness 7mm)
Fields: Off
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 201 mbarg
SiPM HV: 65 V
Number of Events: 10K
Run 1017
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 201 mbarg
SiPM HV: 65 V
Number of Events: 10K
Run 1018
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 217 mbarg
SiPM HV: 65 V
Number of Events: 10K
Run 1019
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 240
SiPM HV: 65 V
Number of Events: 10K
Run 1020 Laser Run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MAX
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Comment: Recieved this error message but run seemed to continue ok and data appeared to be written: 19:56:04.839 2019/11/09 [feov1725MTI00,ERROR] [feoV1725.cxx:1048:read_trigger_event,ERROR] Error: did not receive a ZMQ bank after 100.000000 ms. Stopping run. ╳
Run 1021 Laser Run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
|
105
|
09 Nov 2019 07:29 |
Marco Rescigno | Problem Fixed | MIDAS | this morning problem | frontend process still alive but slow, causing lot of rejected triggers.
stopped and restarted the feov1725 process to fix this |
104
|
09 Nov 2019 00:13 |
Xiang Xiao | Routine | General | Morning data taking | "ERROR INFO: 10:38:10.924 2019/11/09 [feov1725MTI00,ERROR] [feoV1725.cxx:1048:read_trigger_event,ERROR] Error: did not receive a ZMQ bank after 100.000000 ms. Stopping run."
Emailed to Ben.
Run 999
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 233 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1000
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 235 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1001
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 238 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1002
Gas pocket: ON (thinkness 7mm)
Fields: OFF
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 238 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 1003 Laser run (manually stopped)
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Comment: Triger rate too low (~8 Hz), manually stopped
Run 1004 Laser run (manually stopped)
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Comment: Triger rate too low (~8 Hz), manually stopped
|
103
|
08 Nov 2019 22:31 |
Marco | Configuration | Hardware | Adding darkside01 | Wrong MAC address fixed in CERN network setting, now the machine is visible from external network too:
From CERN network (even laptop) can connect by
ssh -XY dsproto@ds-proto-daq2.cern.ch. (same password as local account in ds-proto-daq)
From ds-proto-daq can also connect by:
ssh darkside01
That is to say that the two network card are now associated to two different names.. but the "real" name is still darkside01.
(will fix).
enjoy
|
101
|
08 Nov 2019 10:07 |
Edgar Sanchez | Routine | General | Monitoring Data Taking | Run 995
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 230 mbarg
SiPM HV: 65 V
Number of events: 10k
Rate ~9 Hz
Comment: TPC pressure increased up to 290 mbarg
Run 996
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 225 mbarg
SiPM HV: 65 V
Number of events: 10k
Rate ~9 Hz
Comment: TPC pressure increased up to 240 mbarg
Run 997
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 10k
Rate ~9 Hz
Run 998
Gas pocket: ON (thinkness 7mm)
Fields: OFF
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 10k
Rate ~9 Hz |
100
|
08 Nov 2019 09:09 |
Ben Smith | Configuration | Hardware | Adding darkside01 to the network | The cable has been fixed. Socket 0001/007 is still not active. |
99
|
08 Nov 2019 08:35 |
Ben Smith | Configuration | Hardware | Failed to talk to steering module from DAQ PC | I have failed to communicate with the steering module arduino from the DAQ PC.
The steering module has the most bizarre communication protocol of any device I have used:
* it has a static IP address (192.168.121.2)
* if something connects and sends a command, it doesn't send a response to that device - it sends responses to a different static IP address on a fixed port
* before a device connects, it's ethernet port is not open all the time - it turns it on for a brief period, and if something connects during that period, it remains on; if not, it turns off for a while. I'd estimate something like on for 500ms, off for 500ms.
We are currently using a macbook to connect to the steering module. The macbook is statically assigned IP address 192.168.121.1. When pinging the steering module, then first few pings fail with "no route to host". Eventually one of the pings coincides with the steering module having its ethernet on, and then the steering module keeps its ethernet on and the rest of the pings succeed.
We bought a new NIC for DAQ machine. I assigned it same static IP address (192.168.121.1), added a hole in the firewall (and even tried turning the firewall off for a bit), ensured the correct interface was used for connections to 192.168.121.0/24, but we never get a route to the steering module.
I have run out of things to try (but I may have missed something). My hypothesis is that linux isn't able to negotiate a connection quickly enough, but I may be wrong. It is my last evening at CERN, so I have returned the steering module to be connected to the macbook. Shifters will continue to have to manually change channels rather than having it automated by midas.
I hope that future versions of the steering module will have a more normal network protocol - open a server socket (static if must be, but preferably on DHCP), wait for connections, reply to commands on that same connection. |
98
|
08 Nov 2019 05:14 |
Ben Smith | Configuration | Hardware | Adding darkside01 to the network | The analysis server from Roma (darkside01) is now connected to the local network. It is not yet connected to CERN.
There are 2 network ports on the rear of the machine:
* The port labelled "1":
* MAC: 9c:71:3a:22:d5:62
* Name: enp2s0f0
* Configured for DHCP
* Connected to local switch
* Assigned IP 192.168.1.10 by ds-proto-daq
* The port labelled "2":
* MAC: 9c:71:3a:22:d5:63
* Name: enp2s0f1
* Configured for DHCP
* Should be connected to CERN network
I have set up password-less ssh between ds-proto-daq and darkside01.
There are 3 problems connecting to the CERN network:
1) The long cable that was created does not work. I tried using it to connect ds-proto-daq to socket 0001/06 (i.e. the socket ds-proto-daq is normally connected to) and there is no link light - the cable is broken.
2) Socket 0001/07 does not seem to be operational. I tried connecting ds-proto-daq to socket 0001/07 using the cable we know works, and there was no link light. Either CERN have disabled the connection intentionally, or it is broken.
3) When I used the good cable to connect to the good socket (0001/06), CERN claimed the machine was unregistered. Marco told me that the interfaces have MACs 9c:71:3a:22:d6:4[ab] (rather than 9c:71:3a:22:d5:6[23]), so presumably the wrong MAC addresses were registered with CERN.
So, we need to register the correct MACs, fix the cable, and either get 0001/07 working or connect to a different socket. |
97
|
08 Nov 2019 02:48 |
Ben Smith | Configuration | MIDAS | Enabled dotfile naming in Logger | I have changed `/Logger/Channels/0/Settings/Filename` to start with a dot, so files will be hidden until they are complete.
The current value is `.run%05dsub%03d.mid`.
This will help Pablo with his script for transferring files to EOS. |
96
|
08 Nov 2019 02:31 |
Ben Smith | Routine | Software | New "run type" selection page | I made a new page that makes it easier to switch between laser/noise/physics runs.
It handles setting the most common chronobox trigger settings, and the V1725 self-trigger thresholds.
For the latter, it assumes that the baselines are at 15500. A suggested workflow would be to run
"equalize_baselines.py" in the morning to ensure all channels are at 15500, then you can use this
page to set the self-trigger thresholds for the rest of the day/week without using the python scripts.
The page is available at https://m-darkside.web.cern.ch/?cmd=custom&page=Run%20type |
95
|
08 Nov 2019 02:21 |
Ben Smith | Problem Fixed | Software | Increased max waveform length that we can take | I've increased various thresholds so that we can now take 3000us (3ms) waveforms.
The changes are:
* /Experiment/MAX_EVENT_SIZE in ODB is now 50,000,000
* /Experiment/Buffer sizes/SYSTEM in ODB is now 500,000,000
* max_event_size for V1725 frontend is now 45,000,000 (we use this in several places, so I now have `#define V1725_MAX_EVENT_SIZE 45000000` in v1725CONET2.hxx)
* event_buffer_size for V1725 frontend is now big enough for 10 of these largest events
The main data-taking works smoothly with 3ms traces, albeit at a low event rate.
However protoDisplay segfaults after a few events. The backtrace is random each time, so we're clearly overflowing a buffer somewhere. I will try to look into it, but it will probably be painful and I don't think it's the highest priority issue to fix (it works "fine" for the usual 200us waveforms). |
94
|
07 Nov 2019 23:48 |
Yi Wang | Routine | General | morning data taking | Run 973
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 222 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 974
Gas pocket: ON (thinkness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 222 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 975
Gas pocket: ON (thinkness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 222 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 976
Gas pocket: ON (thinkness 7mm)
Fields: OFF
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
Threshold extend: 5x16 = 80ns
TPC Pressure: 222 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 978 Laser run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MAX
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Number of events: 100k
Run 979 Laser run
Chronobox: External trigger Enable
Chronobox: Enable Channel [ch_enable]: 0x00000000
Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 12us, 5us pre-trigger
SIPM HV: 65V
Number of events: 100k
After laser run:
Switch Laser OFF
In Chronobox:
DIsable "External Triger Enable [ext_trig_ena]0\[0]
Input "0x3F3F3F7F" in "Enable Channel [ch_enable]
|
93
|
07 Nov 2019 02:34 |
Sam | Routine | General | Run 966 Laser Run with SiPMs at 65V, 30us trace | Laser Intensity: MIN
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 30us, 5us pre-trigger
SIPM HV: 65V
MISSING FILE (E.Sanchez) |
92
|
07 Nov 2019 02:16 |
Sam | Routine | General | Run 964 Laser Run with SiPMs at 65V, 30us trace | Laser Intensity: MAX
Threshold: external clock (laser NIM), laser set to 1kHz
Trace length: 30us, 5us pre-trigger
SIPM HV: 65V |
91
|
07 Nov 2019 02:07 |
Yi/Marco/Andrea | Routine | General | morning data taking, purity check | Run 956
Gas pocket: ON (thickness 7mm)
Fields: drift 200 V/cm, extraction 2.8 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
TPC Pressure: >200 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 957
Gas pocket: ON (thickness 7mm)
Fields: drift 200 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
TPC Pressure: >200 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 958
Gas pocket: ON (thickness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
TPC Pressure: >200 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 960
Gas pocket: ON (thickness 7mm)
Fields: drift 500 V/cm, extraction 3.78 kV/cm
Threshold: 200 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
TPC Pressure: >200 mbarg
SiPM HV: 65 V
Number of events: 10k
Run 961
Gas pocket: ON (thickness 7mm)
Fields: OFF
Threshold: 1000 ADC below baseline
Trace length: 200us total, 100 us pre-trigger
TPC Pressure: >200 mbarg
SiPM HV: 65 V
Number of events: 10k |
|