21
11 Mar 2019 15:27
Thomas
Routine
Trigger
New chronobox firmware; run start/stop implemented
> f) However, I found that the frontend program
still consistently failed with this error
23
27 Mar 2019 14:04
Pierre
Configuration
Trigger
Time stamp sync
The ChronoBox latest FW is loaded. Let tme
know if this is what the chronobox should
look like in term of registers.
24
28 Mar 2019 02:18
Pierre
Configuration
Trigger
Test
29
11 Apr 2019 08:20
Thomas
Routine
Trigger
Missing ZMQ banks
I have done a couple longer tests of the DAQ
setup. The runs were done with a high trigger
rate of ~60Hz, with
31
11 Jul 2019 15:52
Thomas
Routine
Trigger
invert first chronobox busy signal
The DAQ seems to be ready for tests with proto-0
tomorrow.
33
12 Jul 2019 02:05
Marco Rescigno
Problem
Trigger
MB1 test in proto-0 setup/1
Tried to get laser sync signal into chronobox
(clkin1 input), apparently all triggers dropped
by chronobox
40
16 Jul 2019 02:41
Marco Rescigno
Problem
Trigger
Busy handling
This morning tried to get some data with
Vbias=65 V, which seems better for the SiPM
in MB1.
118
11 Nov 2019 23:57
Yi Wang
Problem Fixed
Trigger
ID 117 problem is fixed
The problem reported in ID 117 is somehow
fixed this morning.