Run 1148
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
problem DAQ, forced to stop manually
Run 1149
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 380 Hz
Run 1150
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 200 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 310 Hz
Run 1151
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 400 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 250 Hz
Run 1152
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 600 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 150 Hz
Run 1153
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 1000 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 5 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 90 Hz
Run 1154
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 2 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 390 Hz
Run 1155
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 200 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 2 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
Run 1156
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 400 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 2 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
Run 1157
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 600 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 2 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
Run 1158
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 1000 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 2 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Rate: 400 Hz
Run 1159
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 100 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 3 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Run 1160
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 200 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 3 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Run 1161
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 400 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 3 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Run 1163
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 600 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 3 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k
Run 1164
Gas pocket: OFF
Fields: 500 V/cm
Threshold: 1000 ADCc below baseline
Trace length: 30us total, 5 us pre-trigger
Coincidence: 3 PDMs
Threshold extend: 5x16 = 80ns
TPC Pressure: 240 mbarg
SiPM HV: 65 V
Number of events: 50k |