HW-Time-Slice Firmware-Filter Software vx2740 Steering Module Reports MVM MVM Vexos MVM-Bug listing MVM TRIUMF Local DS Prototype DS Cryogenic For Shifters BCIT-31 ChronoBox Run Operation DS-DAQ
  CERN DS-Proto0 read-only backup  Not logged in ELOG logo
Message ID: 141     Entry time: 18 Nov 2019 03:03
Author: Julie / Pascal / Edgar 
Type: Routine 
Category: General 
Subject: Random Trigger runs suggested by Simone (4 runs ~ 200 k evts) 

Run 1234  Physics run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Threshold: external clock,  set to 50 Hz

Trace length: 200us, 100us pre-trigger

 Drift field 200 V/cm Extraction 3.78 kV/cm

SIPM HV: 65V

Number of events: 200k

Problem with DAQ at 40k, force to restart manually 

Run 1235  Physics run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Threshold: external clock,  set to 50 Hz

Trace length: 200us, 100us pre-trigger

 Drift field 200 V/cm Extraction 3.78 kV/cm

SIPM HV: 65V

Number of events: 200k

Problem with DAQ at 70k, force to restart manually 

Run 1237  Physics run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Threshold: external clock,  set to 50 Hz

Trace length: 200us, 100us pre-trigger

 Drift field 200 V/cm Extraction 3.78 kV/cm
 

SIPM HV: 65V

Number of events: 40k

Run 1238  Physics run

Chronobox: External trigger Enable

Chronobox: Enable Channel [ch_enable]: 0x00000000

Threshold: external clock,  set to 50 Hz

Trace length: 200us, 100us pre-trigger

 Drift field 200 V/cm Extraction 3.78 kV/cm

SIPM HV: 65V

Number of events: 40k

 

ELOG V3.1.4-cb3afcd8